Varioskan LUX comes equipped with a range of measurement technologies including absorbance and fluorescence intensity with optional luminescence, AlphaScreen and TRF. The instrument selects the measurement wavelength using monochromators or optical filters, depending on which is optimal for each measurement technology. A wide range of optional filters extends the application area remarkably, including luciferase assays, Bioluminescence Resonance Energy Transfer (BRET) assays, Homogeneous Time Resolved Fluorescence (HTRF) assays and many other.
Code | Description |
---|---|
F49210 | Catalog Number: F49210 Unit Size: Each Product Type: Emission Filter Wavelength: 492 nm For Use With (Application): General Terbium measurement |
F46080 | Catalog Number: F46080 Unit Size: Each Product Type: Emission Filter Wavelength: 460 nm For Use With (Application): NanoBRET donor |
F48020 | Catalog Number: F48020 Unit Size: Each Product Type: Emission Filter Wavelength: 480 nm For Use With (Application): BRET donor using wtRluc |
F51060 | Catalog Number: F51060 Unit Size: Each Product Type: Emission Filter Wavelength: 510 nm For Use With (Application): Chroma-glo luciferase CBG68 or CBG99 assay |
F51530 | Catalog Number: F51530 Unit Size: Each Product Type: Emission Filter Wavelength: 515 nm For Use With (Application): BRET2 acceptor using GFP2 |
F52010 | Catalog Number: F52010 Unit Size: Each Product Type: Emission Filter Wavelength: 520 nm For Use With (Application): LanthaScreen measurement of Tb acceptor; HTRF donor measurement of TbGreen |
F52530 | Catalog Number: F52530 Unit Size: Each Product Type: Emission Filter Wavelength: 525 nm For Use With (Application): Pierce green Renilla luciferase assay |
F53030 | Catalog Number: F53030 Unit Size: Each Product Type: Emission Filter Wavelength: 530 nm For Use With (Application): BRET acceptor using eYFP |
F57177 | Catalog Number: F57177 Unit Size: Each Product Type: Emission Filter Wavelength: 571 nm For Use With (Application): AlphaScreen measurement |
F61060 | Catalog Number: F61060 Unit Size: Each Product Type: Emission Filter Wavelength: 610 nm For Use With (Application): Chroma-glo luciferase CBR assay |
F610LP | Catalog Number: F610LP Unit Size: Each Product Type: Emission Filter Wavelength: 610 nm For Use With (Application): NanoBRET acceptor |
F61520 | Catalog Number: F61520 Unit Size: Each Product Type: Emission Filter Wavelength: 615 nm For Use With (Application): AlphaLisa measurement |
F62010 | Catalog Number: F62010 Unit Size: Each Product Type: Emission Filter Wavelength: 620 nm For Use With (Application): General Europium measurement; LanthaScreen measurement of Eu donor; HTRF acceptor measurement of TbGreen; HTRF donor measurement of EuRed and TbRed |
F640LP | Catalog Number: F640LP Unit Size: Each Product Type: Emission Filter Wavelength: 640 nm For Use With (Application): Pierce red firefly luciferase assay |
F66510 | Catalog Number: F66510 Unit Size: Each Product Type: Emission Filter Wavelength: 665 nm For Use With (Application): LanthaScreen measurement of Eu acceptor; HTRF acceptor measurement of EuRed and TbRed |
F47040 | Catalog Number: F47040 Unit Size: Each Product Type: 470/ 40 nm emission filter Wavelength: 470 nm For Use With (Application): Pierce Cypridina and Gaussia luciferase assays |