Varioskan™ LUX multimode microplate reader (Thermo Scientific™)

Designed for bioscience researchers with a wide variety of needs, the Thermo Scientific™ Varioskan™ LUX multimode microplate reader comes equipped with a flexible range of measurement technologies including Absorbance, Fluorescence Intensity, Luminescence, AlphaScreen, and Time-Resolved Fluorescence. The instrument simplifies measurement setup with the automatic dynamic range selection, and its smart safety controls ease workflow and help avoid experimental errors. Varioskan LUX raises the bar for reliability and ease, with technology that works in researchers’ best interest.
The Varioskan LUX multimode reader has received HTRF™ certification from Cisbio Bioassays and DLReady™ validation from Promega Corporation.

Key Features

The Varioskan LUX is a modular, upgradable instrument that provides excellent usability across a variety of applications.
  • Up to five measurement technologies: Absorbance (UV-Vis), Fluorescence intensity (incl. FRET), Luminescence (direct and filtered), AlphaScreen/AlphaLISA and Time-resolved fluorescence (incl. TR-FRET/hTRF)
  • Filter and monochromator optics
  • Spectral scanning for assay optimization
  • Five measurement modes including end point, kinetic, spectra, kinetic spectra and multipoint
  • Integrated gas control module for setting CO2 and O2 concentrations for cell based assays
  • Simultaneous dispensing and measurement for signal monitoring at the start of a reaction
  • Automatic dynamic range selection, based on signal intensity of each well
  • Smart safety controls designed to identify and alert the user of potential problems before they happen
  • Automated instrument calibration and self-diagnostics for reliable performance
  • Certified HTRF compatible reader by CisBio Bioassays
  • Validated DLReady by Promega Corporation
Varioskan LUX is paired with the powerful and intuitive SkanIt Software, providing excellent usability and flexibility.
  • License free—Each user can install the software on his/her computer
  • Intuitive and flexible interface for multiple users and assays
  • Innovative Virtual Pipetting Tool makes it easy to define samples to plate layout
  • Measurement data is continuously saved to the database, so there’s no data lost due to unexpected interruptions such as power outages or accidental aborting
  • Simplified data processing and export
    • Export data in a single mouse click, or have it emailed automatically at the end of the run
    • Several file formats for exporting results: *.xlsx, *.pdf, *.xml, and *.txt
  • Shows real-time spectra and kinetic curves during the measurement
  • Built-in calculations for data analysis (e.g. blank subtraction, average/SD/CV%, standard curve, dose response, quality control, classification, kinetic and spectral analysis, custom formula, etc.)
  • Comprehensive result reports with traceability to runtime actions and settings
  • Two editions available: Research Edition for life science researchers, and Drug Discovery Edition which offers features needed for the FDA 21 CFR Part 11 compliance.
The Varioskan LUX is modular and upgradeable, so you can build the system that best suits your needs. For more information, contact a sales representative.

Order Codes

Code Description
VLBLATD2 Catalog Number: VLBLATD2
Unit Size: Each
Measurement Technology: Absorbance, Fluorescence Intensity, Luminescence, Time-resolved Fluorescence, AlphaScreen
Reading Options: Top and Bottom
No. of Dispensers: 2
VL0L00D0 Catalog Number: VL0L00D0
Unit Size: Each
Measurement Technology: Absorbance, Fluorescence Intensity, Luminescence
Reading Options: Top
No. of Dispensers: None
VL0L0TD0 Catalog Number: VL0L0TD0
Unit Size: Each
Measurement Technology: Absorbance, Fluorescence Intensity, Luminescence, Time-resolved Fluorescence
Reading Options: Top
No. of Dispensers: None
VLBL00GD0 Catalog Number: VLBL00GD0
Unit Size: Each
Measurement Technology: Absorbance, Fluorescence Intensity, Luminescence
Reading Options: Top and Bottom
No. of Dispensers: None
VLBL00GD1 Catalog Number: VLBL00GD1
Unit Size: Each
Measurement Technology: Absorbance, Fluorescence Intensity, Luminescence
Reading Options: Top and Bottom
No. of Dispensers: 1
VLBL00GD2 Catalog Number: VLBL00GD2
Unit Size: Each
Measurement Technology: Absorbance, Fluorescence Intensity, Luminescence
Reading Options: Top and Bottom
No. of Dispensers: 2
VLBL0TGD0 Catalog Number: VLBL0TGD0
Unit Size: Each
Measurement Technology: Absorbance, Fluorescence Intensity, Luminescence, Time-resolved Fluorescence
Reading Options: Top and Bottom
No. of Dispensers: None
VLBL0TGD1 Catalog Number: VLBL0TGD1
Unit Size: Each
Measurement Technology: Absorbance, Fluorescence Intensity, Luminescence, Time-resolved Fluorescence
Reading Options: Top and Bottom
No. of Dispensers: 1
VLBLATD0 Catalog Number: VLBLATD0
Unit Size: Each
Measurement Technology: Absorbance, Fluorescence Intensity, Luminescence, Time-resolved Fluorescence, AlphaScreen
Reading Options: Top and Bottom
No. of Dispensers: None
VLBL0TGD2 Catalog Number: VLBL0TGD2
Unit Size: Each
Measurement Technology: Absorbance, Fluorescence Intensity, Luminescence, Time-resolved Fluorescence
Reading Options: Top and Bottom
No. of Dispensers: 2
VLBLATGD0 Catalog Number: VLBLATGD0
Unit Size: Each
Measurement Technology: Absorbance, Fluorescence Intensity, Luminescence, Time-resolved Fluorescence, AlphaScreen
Reading Options: Top and Bottom
No. of Dispensers: None
VLBLATGD1 Catalog Number: VLBLATGD1
Unit Size: Each
Measurement Technology: Absorbance, Fluorescence Intensity, Luminescence, Time-resolved Fluorescence, AlphaScreen
Reading Options: Top and Bottom
No. of Dispensers: 1
VLBLATGD2 Catalog Number: VLBLATGD2
Unit Size: Each
Measurement Technology: Absorbance, Fluorescence Intensity, Luminescence, Time-resolved Fluorescence, AlphaScreen
Reading Options: Top and Bottom
No. of Dispensers: 2
VLBLATD1 Catalog Number: VLBLATD1
Unit Size: Each
Measurement Technology: Absorbance, Fluorescence Intensity, Luminescence, Time-resolved Fluorescence, AlphaScreen
Reading Options: Top and Bottom
No. of Dispensers: 1
VLBL00D2 Catalog Number: VLBL00D2
Unit Size: Each
Measurement Technology: Absorbance, Fluorescence Intensity, Luminescence
Reading Options: Top and Bottom
No. of Dispensers: 2
VLBL0TD2 Catalog Number: VLBL0TD2
Unit Size: Each
Measurement Technology: Absorbance, Fluorescence Intensity, Luminescence, Time-resolved Fluorescence
Reading Options: Top and Bottom
No. of Dispensers: 2
Click here for more info